- home > Supply > Chengdu inverter manufacturers it? Chengdu which DC panel manufacturers? Supply Inverter?
| Information Name: | Chengdu inverter manufacturers it? Chengdu which DC panel manufacturers? Supply Inverter? |
| Published: | 2011-09-28 |
| Validity: | 30 |
| Specifications: | 10KG |
| Quantity: | 1.00 |
| Price Description: | |
| Detailed Product Description: | Science and Technology Development Co., Ltd. Shenzhen Keruiaite special screen-specific production of sine wave inverter dc power inverter, a large number of supply, high quality low price, welcome customers to consult with
l load overload, inverter output power off, remove the overload after 50 seconds, automatically restore power output, this feature is especially suitable for unattended communication base station;
l support communication, providing RS232 interface (PIN2, 3,5), using real-time understanding of the power monitoring software work; (Note: This series 500VA models no this function)
l provide two passive dry point, respectively, for the DC input failure (RS232 PIN6, 7) and communication failure alarm output (RS232 PIN8, 9) (Note: This series 500VA models no this function)
l support for non-DC power capabilities, you can only run under the state of electricity. This feature allows the inverter into use early, and then install the battery. (Note: This series 500VA models no this function)
Two, CT description of each model series inverter
XX/220-XXXX
XX. . . . . . Nominal input DC voltage (Vdc)
220. . . . . . Nominal output sine wave voltage (Vac)
XXXX. . . . . . Nominal Output Power (VA)
Third, the sine wave inverter technology indicators
500VA 1000VA 2000VA 3000VA 4000VA 5000VA 6000VA
DC Input: Nominal input voltage (Vdc)
Rated input current (A)
Input DC voltage range
Anti-noise current ≤ 10% irrigation
AC bypass input, allowing the bypass voltage (Vac) 220 ± 25%
Rated input current (A) 1.8 3.6 7.2 10.8 14.5 15.9 19.1
Bypass conversion time (ms) ≤ 5ms
AC output, the rated capacity (VA) 500VA 1KVA 2KVA 3KVA 4KVA 5KVA 6KVA
Rated output power (W) 400W 800W 1600W 2400W 3200W 3500W 4200W
Rated output voltage and frequency 220Vac, 50HZ
Rated output current (A) 1.8 3.6 7.2 10.8 14.5 15.9 19.1
Output voltage accuracy (V) 220 ± 1.5%
Output Frequency Accuracy (Hz) 50 ± 0.1%
Waveform distortion (THD) ≤ 3% (linear load)
Dynamic response time of 5% (load 0 ← → 100%)
Power factor (PF) 0.8 0.7
110% overload for 30 seconds
Inverter efficiency ≥ 85% (80% resistive load)
Bypass conversion time (ms) ≤ 5ms
Work environment
Dielectric strength (input and output) 1500Vac, 1 分钟
Noise (1 m) ≤ 40dB
Ambient temperature -25 ℃ ~ +50 ℃
Humidity 0 ~ 90% non-condensing
With altitude (m) ≤ 1000
Dimension Standard Rack Table V (D × W × H) (mm)
Protection
Input voltage, input over-voltage protection; output overload, output short circuit protection
Inverter input DC voltage (Vdc) (error: + / -0.5 ~ 1V)
Series 24V 12V 48V series 110V series 220V series Series
Rated input voltage (Vdc) 12V 24V 48V 110V 220V
Input DC voltage range (Vdc) Operating Voltage 9.8V-14.5V operating voltage 20V-30.5V Operating voltage 40V-58.8V Operating Voltage 90V-132V operating voltage 180V-270V
Open electrical 10.2V - 14.2V voltage power voltage 21.5V-29.5V power voltage 42V - 57V power voltage 94V - 130V Power Voltage 190V - 265V
Description:
1, in order to protect the battery, the battery voltage is switched on only when the voltage is within the scope of the inverter in order to boot.
2, boot into the working state, as long as the battery voltage at the operating voltage range, the inverter can work properly. When the battery voltage down to the lower limit will start voltage and low voltage warning, continued to decline to work off the inverter voltage limit.
Fourth, the use of sine wave inverter
l Installation
1, the installation of the inverter must have some knowledge of electrical theory and practical experience of technical staff.
2, open the box, check that you have complete (an AC input line and a manual);
3, select the ventilation, clean installation environment;
4, confirm the DC power supply output voltage and (or) battery voltage and inverter input voltage DC power requirements in line;
5, confirm the power of positive and negative polarity, high-potential is positive, low negative potential (for example:-48VDC power supply 0V side is positive,-48V for the negative side, +24 V power supply +24 V terminal is positive, 0V side is negative);
6, received the positive terminal on the inverter's positive (marked with "+"), negative to negative terminal on (marked with "-"). To ensure reliable connection;
7, AC input from the accessories out of the bag line, which will be marked on one end of the chassis "AC IN" socket in the other end into the mains socket (Note: The AC input ground wire must be grounded line! Prohibit exchange AC input and output common zero line!);
8, the load input line connected to the inverter output jack (labeled "AC OUT") on.
l boot (first open inverter, and then open the load!)
9, confirm the power of the DC input, AC output connections are correct and reliable;
10, if the DC input switch, turn on the switch (located in the rear of the chassis)
11, according to "switch" button ("1" means open, "0" means off) inverter issued a "tick" sound, and enter the self-state that has been opened.
Description: The self-test status - power inverter in a stable output, check the external environment and the inverter itself is normal, if the inverter and the mains all the normal parameters of state, the inverter will stabilize or reverse the work in the city change state (main supply stable electricity output in the electricity, the battery main supply stability in the inverter output), this process takes about 10 seconds, during which the LED is lit from left to right, loop twice.
Off (off load first, then turn off the inverter power supply!) Press the "switch" button ("1" means open, "0" means off) LED lights dim at this time inverter off. Mute, if the inverter power failure during operation, the system will sound and light alarm, sound alarm can use the "mute" button to mute, press and hold "Mute" (about 3 seconds), alarm sound will be Close; again keep pressing the "mute" (about 3 seconds), alarm sound is turned on. The same alarm, mute will not automatically open when there is another warning, regardless of whether the last alarm is muted, the power automatically turn on the sound alarm.
Fifth, sine wave inverter to maintain information
l graphics (front, from left to right: 1,2,3,4,5,6)
1) The "switch" button (black); 2) the "mute" button (red); 3) "electricity output" light (green);
4) "Inverter output" lamp (blue); 5) "Battery Fault" LED (red); 6) "load fault" lamp (red)
Sixth, sine wave inverter mechanical properties
Mechanical Dimensions (ABCD type of horizontal or 19-inch rack enclosure chassis, EF type for the vertical case)
1, an AC power input line (0.5-3KVA); 2, use the manual one; |
Admin>>>
You are the 5490 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen Keruiaite Technology Development Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 5490 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen Keruiaite Technology Development Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility